OASIS ® FLUIDISED BEAD BED

 

The OASIS® fluidised bead bed system is designed for patients with critical care needs, not necessarily related to a pressure sore risk category.
Injuries such as burns or other exudating wounds may benefit from air fluidised therapy by reducing skin maceration and helping to manage incontinence. the system also allows patients to be repositioned more easily. The OASIS system incorporates features reflecting  your needs within the critical care setting.

 
bullet

Variable height - no side steps required

bullet

Detachable control unit - no disruption for patient or carer during servicing

bullet

Variable fluidisation - supports patients in lying and sitting position

bullet

Integral warming/cooling system - effective regulated temperature control

Variable Height

bullet

Adjustable between 830-1130mm

bullet

Ease of access for nursing staff

bullet

Facilitates patient mobilisation

Temperature Control-Warming and Cooling

bullet

Integral warming and cooling system

bullet

More effective regulation of bed temperature

Detachable Control Unit

bullet

Transportable

bullet

reducing the need to replace the entire system in the event of servicing or repair-less disruption for the patient and carer

bullet

Sophisticated yet easy to use

bullet

Transparent control cover prevent accidental operation

Variable Fluidisation

bullet

Increases and decreases the airflow within the system

bullet

'Fluid' density can be increased to provide a firmer surface

bullet

Allows 'stepping down' from air fluidisation thearapy

bullet

Aids mobilisation of patient

Multifilament Polyester Mesh 35 Micron Cover

bullet

Compeletly removable and washable

bullet

Durable but soft

bullet

Fluid and air permeable

bullet

Conforms to the contours of the body

bullet

Assists with patient positioning

bullet

Extra wide option available

   

Filters

bullet

Condensate filter-filters ambient air before it is passed over the condenser unit

bullet

Dust filter-ensures that only clean air is blown into the system

bullet

Provides a pro-active approach to Infection Control

CPR

bullet

Within 10 seconds

bullet

Easy to use

bullet

Easy access

Audible and Visual Alarm System

bullet

LED and audible alarm on temperature difference of more than +/-3 º C between set temperature and actual temperature of the 'dry fluid'

bullet

Visual and audible alarms for temperatures of over 40 º C

bullet

Mute button-mutes audible alarm

Beads

bullet

High pH values (pH 9-11)-minimises bacteria growth

bullet

Eliminates nutrition base for harmful bacteria

bullet

Encapsulates body fluids

bullet

Helps eliminate odours

bullet

Low relative humidity

Hand and Foot  Control

bullet

On/Off fluidisation

bullet

Allows on/off adjustment to be made even at the patient's side

 

TECHNICAL SPECIFICATION

 

Back